ED6000T Minuteman 6kVA On-line Tower UPS

SKU: ED6000T
  • True on-line topology with pure sine wave output
  • Parallel configurations for 6, 12, 18 and 24kVA
  • LCD and LED visual indicators
  • Extended runtime with external battery packs
  • Digital signal processor (DSP) controlled
  • Intelligent self-diagnosis
  • Emergency Power-off (EPO)
  • Communications capability via RS-232 or optional SNMP (2 slots)
More details...
MPN: ED6000T
MSRP Price: $3,599.00
Price: $3,599.00
Add to List
DWG Dealer Program Become a DWG Dealer to see your pricing. Dealer pricing, quoting, volume discounts, and sales support on thousands of products.


Product Details

The Endeavor Tower Series is yet another option for applications that require the best protection available. This feature-rich, single-phase, true online UPS has been designed to support large loads for data centers, large telephone systems, and other missioncritical applications.

A perfectly regulated, continuous sine wave output with zero transfer time offers guaranteed uptime and compatibility with all equipment types.


Specifications


  • Model Number - ED6000T
  • Topology - Double Conversion On-Line, True Sine Wave
  • Maximum power capacity - 6000VA/4200Watts
  • Number of Phases - Single (1Ø 2W +G)
  • Nominal/ Acceptable Input Voltage - 208VAC / 0 - 300VAC
  • Voltage Range - 160* - 280VAC
  • Power Factor Correction - >98% at Full Load
  • Frequency Limits - 50/60Hz +/-5Hz autosensing
  • Low/High Voltage Transfer Point - 160V resets to utility power at 175V or higher / 280V resets to utility power at 265V or lower
  • Protection - Re-settable Circuit Breaker
  • Waveform Type - True Sinewave
  • Nominal Voltage - 120VAC & 208/240VAC
  • Voltage Regulation - +/-2% (until Low Battery Warning)
  • Frequency - 50/60Hz +/-0.2Hz (unless synchronized to utility)
  • Voltage T.H.D. - <3% (Linear load)
  • Dynamic Response - +/-5% @ 100% Load change in 100ms
  • Transfer Time - 0ms
  • Slew Rate - <1Hz / second
  • Efficiency (Line Mode) - >87% (Full Load)
  • Crest Factor - 3:01
  • Overload Capacity - >105% - <155% for 160 seconds, >156% shutdown immediately
  • Protection - Over-Current, Short-Circuit and Latching Shutdown
  • Surge Energy Rating/ Capability - 1050 J / 6500 Amps total
  • Surge voltage let-through - <5% (as a percentage of an applied ANSI C62.41 Cat. A +/-6KV)
  • Noise Filter - Normal and common mode EMI/RFI suppression
  • Audible Noise at 1 m (3 ft.) - <50dB
  • BatteryType - Sealed, Non-Spillable, Maintenance Free, Value Regulated, Lead Acid
  • Typical Recharge Time - 8 hours from total discharge
  • Typical Battery Life - 3 - 5 years, depending on the number of charge and discharge cycles, and ambient temperature
  • System Voltage - 240VDC
  • Quantity/Rating - 20-12V7.2Ah
  • Runtime (full/half load) - 8/21 minutes
  • Operating Temp (max) - 0 to 40°C (+32 to +104°F) <2000m (<+6700 ft); 0 to 35°C (+32 to +95°F) at 3000m (+10,000 ft)
  • Storage Temp - -15 to +45°C (+5 to +113°F)
  • Operating/Storage Humidity - 30 - 90% Non-Condensing
  • Storage Elevation - 0 to 15,000m (0 to +50,000 ft)
  • Size - Net D x W x H - 25.4 x 11.4 x 29.4 in; 645 x 290 x 748mm
  • Weight - Net - 275 lb (125 kg)
  • Size – Shipping D x W x H - 31.9 x 18.4 x 38.5 in; 810 x 468 x 961mm
  • Weight - Shipping - 313 lb (142 kg)
  • Safety and Approvals - UL 1778, cUL (CSA 22.2 no. 107.1), CE (EN62040-1-1)
  • EMC - CE (EN62040-2, EN61000-3-2, EN61000-3-3), FCC Class A

ED6000T Specifications Sheet