VIP Distribution. Scalable Service. Trusted Partnerships.
The cart is empty.

UPS-OL3000R Middle Atlantic Premium Online Series UPS Backup Power 2RU 3000VA

SKU: UPS-OL3000R
  • Permanent connection to the battery for zero transfer time eliminating system disruptions and guaranteeing maximum uptime
  • Complete isolation and conditioning of output power with double conversion topology providing the cleanest power possible
  • Reduced ambient noise with quiet variable speed fans
  • Longest run time available in this form factor with the capability to add up to 10 expansion battery packs
  • Front accessible, hot-swappable batteries to eliminate downtime related to UPS power maintenance
  • Pure sine wave output waveform automatically corrects over-voltage and under-voltage conditions
  • Non-critical load shedding
  • EMI/RFI filtering for clean power of connected equipment
More details...
MPN: UPS-OL3000R
UPC: 656747272592
Ordering Notes: Service Professionals Only
MSRP Price: $5,146.00
Web Price: $4,631.40
Add to List
DWG Dealer Program Become a DWG Dealer to see your pricing. Dealer pricing, quoting, volume discounts, and sales support on thousands of products.


Product Details

Rackmount Online Uninterruptible Power Supply (UPS) shall be Middle Atlantic Products model # UPS-OL__ R (refer to chart). Unit shall measure 19.00" W x 3.50" H x __" D and occupy 2 rackspaces. UPS shall have a rear mounting range of 20.69" to 36.19" and not require more than one person to mount. UPS shall have a minimum usable depth of __" (refer to chart). Unit shall operate on 120 VAC/60Hz. Unit shall have a nominal output of 120V. Unit shall have a capacity of __ VA and __ W (refer to chart). Unit shall have (_) NEMA 5- __ receptacles on the rear of the unit (refer to drawing). Unit shall have a priority outlet bank consisting of _ outlets dedicated to ensure maximum run time of critical components. Unit shall have a non-critical outlet bank consisting of _ outlets dedicated to load shedding (refer to drawing). Unit shall be IP enabled when used with optional IP Expansion card, model# UPS-OLIPCARD. Rackmount UPS shall include a 10' power cord with NEMA __ (refer to chart) plug. UPS shall have surge suppression that utilizes a clean line-to-neutral design that does not pass noise contamination to ground. Rackmount UPS shall have a hot swappable battery that allows for a __ minute run time at half load and a __ (refer to chart) minute run time at full load. Rear of unit shall have inputs that allow for the installation of up to __ additional hot swappable batteries (refer to chart). Rackmount UPS shall meet the EU RoHS Directive 2011/65/EU. Rackmount UPS shall utilize Middle Atlantic Power Manager software. Rackmount UPS shall be warrantied to be free from defects in materials and workmanship under normal use and conditions for a period of 3 years; battery shall be warrantied for a period of 2 years. Rackmount UPS shall be UL listed to US and Canadian safety requirements and FCC/IC Class A or B.


Specifications


CONFIGURATION

  • Capacity (VA) - 3000VA
  • Capacity (Watts) - 2700W

INPUT

  • Cord Length and Plug Type - 10ft, NEMA L5-30P
  • Input Voltage Range - 100~125Vac
  • Input Frequency Range - 50 / 60Hz
  • Input Power Factor - 0.99
  • Cold Start - Yes

OUTPUT

  • Output Waveform - Sine wave
  • Output Voltage (regulated) - 100, 110, 115, 120, 125Vac (Configurable) ±2%
  • Output Frequency - 50 / 60Hz (Auto-Sensing or Configurable) ±0.25Hz
  • Transfer Time - 0ms
  • Rated Power Factor - 0.9
  • Harmonic Distortion - THD < 3% at Linear Load, < 5% at Non-linear Load
  • Crest Factor - 3:01
  • ECO Mode Voltage Regulation - ±10%, ±15% (Configurable)
  • UPS Outlets - 6) NEMA 5-20R, (1) L5-30R
  • Thermal Dissipation - 1116 BTU/hr
  • Audible Noise (@1.5m) - < 50dBA

PROTECTION

  • Surge Protection - IEC 61000-4-5 Level 3
  • Phone / Network Protection - RJ11/RJ45 (One In/One Out)
  • Overload Protection - Line Mode: 105~125% Load for 1 min, 126~150% Load for 10 sec Battery Mode: 105~130% Load for 10 sec, 131~150% Load for 2 sec
  • Short Circuit Protection - UPS Output Cut off Immediately or Input Fuse / Circuit Breaker Protection

BATTERY

  • Specifications - (6) 12V/9AH
  • Full Load Runtime (estimated) - 4min
  • Half Load Runtime (estimated) - 11min
  • Recharge Time (Typically) - 5 hours for 0-100% Capacity; 4 hours for 0-90% Capacity
  • Sealed, Maintenance Free - Yes
  • Hot-Swappable - Yes

STATUS INDICATORS

  • LCD Screen - Multi-Function LCD Readout that Supports: (19) Types of Read Out, (22) Types of Function Setting, (5) Event Logs
  • LED Indicators - Power On (White), Line Mode (Green), Battery Mode (Yellow), Bypass Mode (Yellow), Fault (Red), Replace Battery (Red)
  • Audible Alarms - Battery Mode, Battery Low, Overload, UPS Fault

ENVIRONMENT

  • Operating Temperature - 32° to 104° F ( 0° to 40° C)
  • Operating Relative Humidity - 0 to 90% Non-Condensing

MANAGEMENT

  • On-Device Features - Self-Test, Auto-Charge, Auto-Restart, Auto-Overload Recovery
  • Connectivity Ports - (1) Serial Port (RS232), (1) USB Port, (1) Relay Out
  • Expansion Slot - (1) Expansion Slot for optional remote management cards (With optional UPS-OLIPCARD)

SOFTWARE

  • Power Management Software - Middle Atlantic Power Manager Software

PHYSICAL

  • Net Weight - 68.2lbs (31kg)

SAFETY

  • Conformance Approvals - UL and FCC
  • RoHS - RoHS Compliant

UPS-OL3000R Specifications PDF


Product Reviews

Write your own review

 

Rate this product: