FP-2500E TAKEX 33' Ultraviolet Flame Sensor and 33' Dual Element PIR Sensor Relay Output N/O - N/C Power 10 - 30VDC

SKU: FP-2500E
Brand: Takex

FP-2500E

Features

  • High sensitivity ultraviolet flame sensor + wide angle intrusion PIR
  • Dual output modes; AND/OR
  • Forced output mode following continued flame detection
  • Alarm memory function
  • Multi-zone PIR technology provides pet immunity up to 20kg (40lbs)
  • PIR area adjustment
  • Detection timer

A combination UV flame sensor and wide-angle PIR with up to 10m flame and intrusion detection for safer indoor protection of your premises.

More details...
MPN: FP-2500E
MSRP Price: $272.00
Web Price: $272.00
Add to List

Already a DWG Dealer? - Sign In to view pricing.



Product Details

FLAME PASSIVE SENSOR

FLAME DETECTION AT 10m(33ft.) AND INTRUSION DETECTION WIDE ANGLE 10m(33ft.), WITH COMPACT DESIGN! IDEAL COMBINATION SENSOR TO MINIMIZE NUISANCE ALARM AND REALIZE SAFER INDOOR PROTECTION OF YOUR PREMISE

TWO OUTPUT MODES SELECTABLE

Two output modes are available; "AND" detection mode and "Individual" detection mode.
• In "AND" detection mode, an alarm signal is output when both flame and passive infrared sensor detect during the selected AND timer.
• In "Individual" detection mode, flame or passive alarm signal is output when either the flame sensor or passive sensor detects.

FORCED OUTPUT OPERATION

The flame sensor outputs flame alarm signal after continued detection for a certain period of time, or detects twice during the selected AND timer even in "AND" detection mode, without any detection by passive sensor.

ALARM MEMORY

It can be easily identified by Alarm memory indication (flame and passive sensor individually) which sensor is activated. Memory LED blinks for 3 min. and lights on for 47 min. after alarm activation.

PET IMMUNITY (Passive Sensor)

Multiple Zone Technology ensures 40 lbs. (20kg) pet immunity with outstandingly high performance and reliability.

AREA ADJUSTMENT (Passive Sensor)

The coverage pattern can be adjusted to different mounting heights by moving the inner unit.

OPERATION SET-UP BY DETECTION TIMER (Flame Sensor)

The alarm will be activated only when the sensor detects a flame (ultraviolet rays) for longer time than set time. Two detection times are selectable by DIP switch on the sensor. < 1 sec., 3 sec. >

Specifications

  • Detection system - [Flame Sensor] Ultraviolet rays (Detection wave length 185 to 260nm)
    [PIR Sensor] Passive infrared
  • Coverage - [Flame Sensor] 33' (10m) with 2.75' (7cm) lighter flame in front Approx. 120° conically
    [PIR Sensor] Wide Angle 33' (10m)
  • Sensitive zone - [PIR Sensor]
    Max. 29 pairs
  • Area adjustment
    - [PIR Sensor] 3 steps
  • Supply voltage - 10V to 30VDC (non-polarity)
  • Current consumption - 20mA Max.
  • Alarm output - Individual mode:
    Flame sensor output (From ALARMâ‘  terminal)
    • Dry contact relay (Semi-Conductor) (N.O./N.C. selectable)
    • Contact operation : Detection time + off delay. (Approx. 2 sec.)
    • Contact capacity : 30V (AC/DC) 0.25A Max. (resistive load)
    Passive sensor output (From ALARMâ‘¡ terminal)
    • Dry contact relay (Semi-Conductor) (N.O./N.C. selectable)
    • Contact operation : One shot (Approx. 2 sec.)
    • Contact capacity : 30V (AC/DC) 0.25A Max. (resistive load)
    AND mode:
    Forced flame signal output (From ALARMâ‘  terminal)
    When the flame sensor detects a flame twice during the selected AND timer. (Detection time + off delay. Approx. 2 sec.)
    Or
    When the flame sensor continues to detect a flame for flame duration time 15 or 30 sec. (Detection time after 15/30 sec + off delay. Approx. 2 sec.)
    ・Dry contact relay (Semi-Conductor) (N.O./N.C. selectable)
    ・Contact capacity : 30V (AC/DC) 0.25A Max. (resistive load)
    AND detection signal output (From ALARMâ‘¡ terminal)
    When both passive and flame sensors detect during the selected AND timer. (Detection time, Min. 2 sec.)
    ・Dry contact relay (Semi-Conductor) (N.O./N.C. selectable)
    ・Contact capacity : 30V (AC/DC) 0.25A Max. (resistive load)
  • Alarm memory - Reset after blinking (3 min) and lighting (47 min)
    (Operate flame and passive LED individually)
  • Tamper output - Dry contact relay N.C.
    (Activated when the front cover is detached)
    Contact capacity: 30V (AC/DC) 0.1A Max. (resistive load)
  • LED indicator - [Flame Sensor] Red LED:
    • Lighting at alarm (Detection time + off delay. Approx. 2 sec.)
    • Blinking (3 min) and Lighting (47 min) at memory

  • [PIR Sensor] Red LED:
    • Lighting at alarm (One shot, Approx. 2 sec.)
    • Blinking (3 min) and Lighting (47 min) at memory
    • Lighting at trouble.
  • Functions - [Flame Sensor]
    Detection timer (1sec, 3sec)
  • Sensitivity adjustment - [Flame Sensor]
    Detection sensitivity (H [100%], L[50%])
    *Detection sensitivity can be set only at "Individual" mode.
    *H[100%] is fixed at "AND" mode.
  • Mounting position - Indoor wall surface (Ceiling with optional attachment “BCW-401â€)
  • Wiring - Terminals
  • Weight - Approx. 120g
  • Appearance - Resin
  • Ambient temperature - 5°F to +131°F (-15°C to +55°C) without condensation