Indoor Outdoor Rate of Rise Heat Detector
The MP Series is a standard THERMOFLEX single circuit, Normally Open contacts detectors, in which the connectivity is modified with pigtail leads that extend through a seal plate.This provides for enhanced protection against corrosive or moisture-laden environments.
This detector is suitable for use in areas where condensation or corrosion can have harmful effects on circuit wiring connected to standard terminals. Its seal plate (with extended pigtail leads) will mount onto a typical cast exterior back box.The detector is connected to a fire alarm system's input circuit as an initiating device.The internal contacts are normally open, and will close when the detector operateseither on a rate of temperature increase, or if the releasing temperature is reached. It is often installed with an addressing module if it is to be annunciated as a specific room or space, e.g. electrical room, garbage compactor, etc. With its non-metallic diaphragm, the detector can operate normally at low temperatures, making it suitable for non-heated or chilled environments including garages and carports.
This detector is suitable for use in areas where condensation or corrosion can have harmful effects on circuit wiring connected to standard terminals. Its seal plate (with extended pigtail leads) will mount onto a typical cast exterior back box.The detector is connected to a fire alarm system’s input circuit as an initiating device.The internal contacts are normally open, and will close when the detector operateseither on a rate of temperature increase, or if the releasing temperature is reached. It is often installed with an addressing module if it is to be annunciated as a specific room or space, e.g. electrical room, garbage compactor, etc. With its non-metallic diaphragm, the detector can operate normally at low temperatures, making it suitable for non-heated or chilled environments including garages and carports.
Fire Detection Devices Ltd. heat detectors for fire alarm systems comply with UL 521 Heat Detectors for Fire Protective Signaling Systems and ULC S531 Standard for Heat Actuated Fire Detectors for Fire Alarm Systems. The UL/ULC control number is 41H9, file number S2406. CSFM listing #7270-1110:0100. Detectors featuring wire (pigtail) leads are included in these documents.
The detector is installed using rain-tight conduit and a standard, approved weatherproof electrical enclosure. A neoprene (or similar gasket supplied with the back box), is installed between the detector’s seal plate and the back box. The wire leads are connected to the initiating circuit inside the enclosure. Unused threaded openings are sealed with threaded plugs. A decorative anodized aluminum cover ring snaps over the detector to complete the installation.
1000137-1 Specifications PDF